Bourns Inc. 2036-40-B2LF
- 2036-40-B2LF
- Bourns Inc.
- GDT 400V 20% 10KA THROUGH HOLE
- Gas Discharge Tube Arresters (GDT)
- 2036-40-B2LF Лист данных
- Axial Cylinder, 3 Lead (Radial Bend)
- Axial Cylinder, 3 Lead (Radial Bend)
- Lead free / RoHS Compliant
- 18796
- Запасы спот / разрешенные дилеры / излишки на заводе
- Гарантия качества на 1 год 》
- Нажмите, чтобы узнать цены
Part Number 2036-40-B2LF |
Category Gas Discharge Tube Arresters (GDT) |
Manufacturer Bourns Inc. |
Description GDT 400V 20% 10KA THROUGH HOLE |
Package Axial Cylinder, 3 Lead (Radial Bend) |
Series Mini-TRIGARD? 2036 |
Mounting Type Through Hole |
Package / Case Axial Cylinder, 3 Lead (Radial Bend) |
Tolerance ±20% |
Number of Poles 3 |
Voltage - DC Spark Over (Nom) 400V |
Impulse Discharge Current (8/20µs) 10000A (10kA) |
Fail Short No |
Package_case Axial Cylinder, 3 Lead (Radial Bend) |
2036-40-B2LF Гарантии
• Ответьте оперативно
• Гарантированное качество
• Глобальный доступ
• Конкурентоспособная рыночная цена
• Универсальные услуги цепочки поставок
Jinftry, это ваш самый надежный поставщик компонентов, добро пожаловать, чтобы отправить нам запрос, спасибо!
У вас есть вопросы о 2036-40-B2LF ?
Не стесняйтесь связаться с нами:
+86-755-82518276
+8615019224070, annies65, +8615118125813
568248857, 827259012, 316249462
+8615019224070, +8615118118839, +8615118125813
( Электронная почта в первую очередь )
Комментарии
Bourns Inc.
2036-42-SM-RPLF
GDT 420V 20% 10KA SURFACE MOUNT
2049-47-BLF
GDT 420V 20% 10KA SURFACE MOUNT
2017-15-SMH-RPLF
GDT 420V 20% 10KA SURFACE MOUNT
2028-23-C2LF
GDT 420V 20% 10KA SURFACE MOUNT
2027-30-BLF
GDT 420V 20% 10KA SURFACE MOUNT
2046-40-ALF
GDT 420V 20% 10KA SURFACE MOUNT
2027-09-CLF
GDT 420V 20% 10KA SURFACE MOUNT
2095-270-BLF
GDT 420V 20% 10KA SURFACE MOUNT
What is a Ground Fault Circuit Interrupter (GFCI)?
What is a ground fault circuit interrupter? A GFCI is used to detect and prevent ground faults. A ground fault is an accidental current flow to the ground through the human body or other paths, which may result in electric shock injury.
Do you know what the symbols for resistors are?
A resistor symbol is a specific graphic or icon used to represent a resistor in electronic circuit diagrams. This symbol is standardized to help engineers and technicians understand circuit diagrams more easily, allowing them to design better, analyze and maintain electronic systems.
Introduction to starter relays - types, functional principles, fault tests
Start relay introduction:
A relay is an electrical control device. When its input volume (excitation volume) reaches a certain requirement, its output volume (controlled volume) will undergo a predetermined jump. The main function of the relay is to realize automatic control, such as automatic protection, conversion, adjustment, etc. It is widely used in power system, automatic control system, vehicle and other fields. It has the interactive relationship between the control system (mainly swi
Bourns SM91501ALO BMS signal transformer
Bourns SM91501ALO BMS signal transformer
Bourns SM91501ALO's BMS signal transformer is a dual-channel functional isolation transformer module with a built-in common mode choke, used for noise suppression in battery management system (BMS) applications. Bourns SM91501ALO BMS signal transformer is certified and meets the AEC-Q200 standard. This series has 1600VDC working voltage and 4300VDC Hi-Pot isolation voltage. The operating temperature range of these transformers is -40°C--+125°C.
.charact